0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Damping ratio effect analysis of a single-pylon cable-stayed bridge

 Damping ratio effect analysis of a single-pylon cable-stayed bridge
Auteur(s): , , , ,
Présenté pendant IABSE Symposium: Long Span Bridges, Istanbul, Turkey, 26-28 April 2023, publié dans , pp. 976-981
DOI: 10.2749/istanbul.2023.0976
Prix: € 25,00 incl. TVA pour document PDF  
AJOUTER AU PANIER
Télécharger l'aperçu (fichier PDF) 0.53 MB

Damping ratio is an important parameter for large span bridges. Bridges with low damping ratio are susceptible to abnormal vibration, therefore it is significant to monitor the damping ratio of bri...
Lire plus

Détails bibliographiques

Auteur(s): (Department of Bridge Engineering Tongji University, Shanghai, China)
(Department of Civil & Environmental Engineering Embry Riddle Aeronautical University, Florida, USA)
(Department of Civil & Environmental Engineering Shandong Hispeed Grp Innovat Res Inst, Jinan, China)
(Department of Civil & Environmental Engineering Shenyang Jianzhu University, Shenyang, China)
(Department of Bridge Engineering Tongji University, Shanghai, China)
Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Symposium: Long Span Bridges, Istanbul, Turkey, 26-28 April 2023
Publié dans:
Page(s): 976-981 Nombre total de pages (du PDF): 6
Page(s): 976-981
Nombre total de pages (du PDF): 6
Année: 2023
DOI: 10.2749/istanbul.2023.0976
Abstrait:

Damping ratio is an important parameter for large span bridges. Bridges with low damping ratio are susceptible to abnormal vibration, therefore it is significant to monitor the damping ratio of bridges. This study investigates the variation of the damping ratio in the operating environment based on the monitoring data of a single-pylon cable-stayed bridge. The main span of the bridge is 225m.

The bridge is installed with a bridge health monitoring system to monitor the response and environment. An automatic damping ratio extraction method is developed to identify the damping ratios of the bridge. In addition, temperature and traffic monitoring data are analyzed and the effect on the damping ratio is investigated by correlation analysis. The results show that the damping ratio changes due to the operating environment. An increase in temperature leads to a slight decrease in the damping ratio. Traffic load also has an important effect on the damping ratio.

Mots-clé:
Pont à haubans