Case study of a simply-supported channel-box girder under special live load

 Case study of a simply-supported channel-box girder under special live load
Auteur(s): ,
Présenté pendant IABSE Symposium: Large Structures and Infrastructures for Environmentally Constrained and Urbanised Areas, Venice, Italy, 22-24 September 2010, publié dans , pp. 614-615
DOI: 10.2749/222137810796062987
Prix: € 25,00 incl. TVA pour document PDF  
AJOUTER AU PANIER
Télécharger l'aperçu (fichier PDF) 0.05 MB

This paper is about a design and analysis of 64m simply-supported channel-box girder which is a part of expansion project used for hot iron transportation for Lianyuan Steel Plant. Its span, create...
Lire plus

Détails bibliographiques

Auteur(s):

Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Symposium: Large Structures and Infrastructures for Environmentally Constrained and Urbanised Areas, Venice, Italy, 22-24 September 2010
Publié dans:
Page(s): 614-615 Nombre total de pages (du PDF): 8
Page(s): 614-615
Nombre total de pages (du PDF): 8
Année: 2010
DOI: 10.2749/222137810796062987
Abstrait:

This paper is about a design and analysis of 64m simply-supported channel-box girder which is a part of expansion project used for hot iron transportation for Lianyuan Steel Plant. Its span, created the world's largest span record of such bridges. Moreover, the special live load is nearly three times the weight as the UIC. Hence, an innovative combined cross-section is adopted to reduce the structure’s height and meet the clearance requirements under the bridge. Then, the piecewise-cast construction method has been used, so the calculation must take the actual construction process into account. Besides, due to the air and bridge’s thermal performance parameters are not easy to determine, it is difficult to calculate the temperature field generated by the mobile thermal radiation effects.

Hence, based on the above-mentioned characteristics of the bridge, a detailed calculation and comparative analysis are carried out to determine a reasonable cross-section form and dimensions optimize the tension phase and study the bridge’s force status under different temperature modes. The analysis showed that the design of this bridge meets the requirements of relevant codes and has adequate safety factors, the calculation methods and conclusions proposed by this paper can be a reference for similar bridge designs in the future.