0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Case study of a simply-supported channel-box girder under special live load

 Case study of a simply-supported channel-box girder under special live load
Autor(en): ,
Beitrag für IABSE Symposium: Large Structures and Infrastructures for Environmentally Constrained and Urbanised Areas, Venice, Italy, 22-24 September 2010, veröffentlicht in , S. 614-615
DOI: 10.2749/222137810796062987
Preis: € 25,00 inkl. MwSt. als PDF-Dokument  
ZUM EINKAUFSWAGEN HINZUFÜGEN
Vorschau herunterladen (PDF-Datei) 0.05 MB

This paper is about a design and analysis of 64m simply-supported channel-box girder which is a part of expansion project used for hot iron transportation for Lianyuan Steel Plant. Its span, create...
Weiterlesen

Bibliografische Angaben

Autor(en):

Medium: Tagungsbeitrag
Sprache(n): Englisch
Tagung: IABSE Symposium: Large Structures and Infrastructures for Environmentally Constrained and Urbanised Areas, Venice, Italy, 22-24 September 2010
Veröffentlicht in:
Seite(n): 614-615 Anzahl der Seiten (im PDF): 8
Seite(n): 614-615
Anzahl der Seiten (im PDF): 8
Jahr: 2010
DOI: 10.2749/222137810796062987
Abstrakt:

This paper is about a design and analysis of 64m simply-supported channel-box girder which is a part of expansion project used for hot iron transportation for Lianyuan Steel Plant. Its span, created the world's largest span record of such bridges. Moreover, the special live load is nearly three times the weight as the UIC. Hence, an innovative combined cross-section is adopted to reduce the structure’s height and meet the clearance requirements under the bridge. Then, the piecewise-cast construction method has been used, so the calculation must take the actual construction process into account. Besides, due to the air and bridge’s thermal performance parameters are not easy to determine, it is difficult to calculate the temperature field generated by the mobile thermal radiation effects.

Hence, based on the above-mentioned characteristics of the bridge, a detailed calculation and comparative analysis are carried out to determine a reasonable cross-section form and dimensions optimize the tension phase and study the bridge’s force status under different temperature modes. The analysis showed that the design of this bridge meets the requirements of relevant codes and has adequate safety factors, the calculation methods and conclusions proposed by this paper can be a reference for similar bridge designs in the future.