The 1915 Çanakkale Bridge: Geometry and vibration controls for steel tower under construction

The 1915 Çanakkale Bridge: Geometry and vibration controls for steel tower under construction
Auteur(s): , , , ,
Présenté pendant IABSE Symposium: Long Span Bridges, Istanbul, Turkey, 26-28 April 2023, publié dans , pp. 367-375
DOI: 10.2749/istanbul.2023.0367
Prix: € 25,00 incl. TVA pour document PDF  
AJOUTER AU PANIER
Télécharger l'aperçu (fichier PDF) 0.53 MB

The steel towers of the 1915 Çanakkale Bridge is a very slender steel structure with a height of 318 m located in the middle of the Dardanelles Strait in Turkey. The tower of a suspension bridge is...
Lire plus

Détails bibliographiques

Auteur(s): (SK ecoplant, Seoul, South Korea)
(SK ecoplant, Seoul, South Korea)
(SK ecoplant, Seoul, South Korea)
(DL engineering and construction Seoul, South Korea)
(DL engineering and construction Seoul, South Korea)
Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Symposium: Long Span Bridges, Istanbul, Turkey, 26-28 April 2023
Publié dans:
Page(s): 367-375 Nombre total de pages (du PDF): 9
Page(s): 367-375
Nombre total de pages (du PDF): 9
Année: 2023
DOI: 10.2749/istanbul.2023.0367
Abstrait:

The steel towers of the 1915 Çanakkale Bridge is a very slender steel structure with a height of 318 m located in the middle of the Dardanelles Strait in Turkey. The tower of a suspension bridge is in general structurally the most vulnerable in a free-standing state before the main cable installation. Thus, an accurate geometry control during construction is essential to construct within the maximum design tolerance for the main cable installation upon completion of such an independent tower. In order to minimize construction errors, it is important to obtain and analyse data such as the location of the tower top (from GNSS receivers), wind direction and speed (from anemometers), and temperature (from thermometers) for a certain period of time. In addition, AMD (Active Mass Damper) system was adopted for effective vibration control during construction and even in operation. This paper focuses on i) the geometry control of the steel tower during construction and ii) the planning and operation of the AMD system installed for wind-induced vibration control, for the world's slenderest steel structure. Through the above process, we have successfully completed the construction of the final tower block B32, upper crossbeam, and tower saddles. The final construction error of the steel tower was up to about 60 mm in the horizontal directions, far below the design tolerance of 150 mm.