0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Auteur(s):
Médium: article de revue
Langue(s): anglais
Publié dans: Budownictwo i Architektura, , n. 1, v. 12
Page(s): 291-298
DOI: 10.35784/bud-arch.2212
Abstrait:

This paper presents the issues related to the design of the multiple tuned mass dampers (MTMD) for the Municipal Stadium in Poznan. It is focused on the design issues, in particular the selection of parameters of mass dampers, their location at the main structure (in this case the full modal analysis was carried out) and the optimization of dampers parameters (the optimization algorithm DAMP-SYM application was used). The verification of the assumptions made during the design stage was carried out, taking into account the dynamic tests of TMD as well as the measurements on the real object of Municipal Stadium in Poznan.

License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution - Partage dans les Mêmes Conditions 4.0 (CC-BY-SA 4.0) International. Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et que le partage se fait dans les mêmes conditions (license) que l'original. Un lien vers la license (ci-dessus) toit être inclus. Toute altération vis-à-vis de l'original doit être indiquée.

  • Informations
    sur cette fiche
  • Reference-ID
    10476131
  • Publié(e) le:
    25.11.2020
  • Modifié(e) le:
    02.06.2021
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine