The tune of mass dampers for the Municipal Stadium in Poznan
Autor(en): |
Piotr Wielgos
|
---|---|
Medium: | Fachartikel |
Sprache(n): | Englisch |
Veröffentlicht in: | Budownictwo i Architektura, März 2013, n. 1, v. 12 |
Seite(n): | 291-298 |
DOI: | 10.35784/bud-arch.2212 |
Abstrakt: |
This paper presents the issues related to the design of the multiple tuned mass dampers (MTMD) for the Municipal Stadium in Poznan. It is focused on the design issues, in particular the selection of parameters of mass dampers, their location at the main structure (in this case the full modal analysis was carried out) and the optimization of dampers parameters (the optimization algorithm DAMP-SYM application was used). The verification of the assumptions made during the design stage was carried out, taking into account the dynamic tests of TMD as well as the measurements on the real object of Municipal Stadium in Poznan. |
Lizenz: | Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung - Weitergabe unter gleichen Bedingungen 4.0 International (CC BY-SA 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt werden und jede weitere Verbreitung muss unter der gleichen Lizenz veröffentlicht werden. Änderungen gegenüber dem Original müssen ebenfalls angegeben werden. |