0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Risk-Reduction Credit for Very Early Warning Fire Detection at Nuclear Power Plants: From FAQ to Fiction

Auteur(s):
Médium: article de revue
Langue(s): anglais
Publié dans: Civil Engineering Journal, , n. 2, v. 5
Page(s): 309
DOI: 10.28991/cej-2019-03091246
Abstrait:

In 2004, the U.S. Nuclear Regulatory Commission (NRC), with support from the commercial nuclear power industry, adopted the 2001 Edition of National Fire Protection Association (NFPA) Standard 805, “Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants,” as the means by which commercial nuclear power licensees could comply with Title 10 of the Code of Federal Regulations, Part 50.48(c), to replace deterministic fire protection licensing bases with ones that are risk-informed and performance-based.  To facilitate licensee “transitions” to the new licensing bases via NFPA 805, a “Frequently Asked Questions” (FAQs) program, established early during the pilot-plant phase, was expanded to enable use of consensus technical “short_cuts” for fire probabilistic risk assessment (PRA) methods.  These “Fire PRA FAQs” enabled licensees, with NRC approval, to bypass more traditional means of establishing acceptable PRA method enhancements on an interim basis, pending eventual confirmation by test programs and/or more detailed analyses.  The NRC approved several, of which perhaps the most substantial in providing risk reduction benefits was FAQ 08-0046 on “Incipient Fire Detection Systems,” more accurately characterized as “Very Early Warning Fire Detection Systems” (VEWFDSs).  Controversial from the start, the hidden story behind this FAQ’s initial adoption is relevant to examination of the NRC NUREG report that later replaced it and remains in effect today.  This article examines this backstory, tracing recommendations that were proposed and bypassed, then examines alternatives to the current guidance.  These alternatives, which maximize possible risk reduction credit for VEWFDSs at nuclear power plants, remain at least a factor of two less than the current peak NUREG-2180 risk-reduction factor even before the latter accounts for the possibility of fire pre-emption altogether.

Copyright: © 2019 Raymond HV Gallucci,
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

Types d'ouvrages

  • Informations
    sur cette fiche
  • Reference-ID
    10340807
  • Publié(e) le:
    14.08.2019
  • Modifié(e) le:
    02.06.2021
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine