Numerical Simulation of the Blast Resistance of SPUA Retrofitted CMU Masonry Walls
Auteur(s): |
Yi Zhang
Jiahui Hu Wenda Zhao Feng Hu Xiao Yu |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Buildings, 14 février 2023, n. 2, v. 13 |
Page(s): | 446 |
DOI: | 10.3390/buildings13020446 |
Abstrait: |
Through numerical simulation, the blast-resistant performance of spray polyurea elastomer (SPUA) retrofitted concrete masonry unit (CMU) masonry infill walls under far-range blast loading was studied. From an engineering perspective, the effects of boundary conditions and thickness of a SPUA layer on enhancing the blast resistance of masonry infill walls are discussed, and the blast resistance of SPUA-retrofitted and grouted CMU masonry infill walls are compared. It is concluded that the boundary constraint conditions and the anchorage length of SPUA layer have limited improvement on the blast-resistant performance of the wall; the thickness of SPUA layer can significantly improve the blast-resistant performance of the wall as the blast loading increases. In addition, SPUA retrofitting shows relatively better performance to reinforce masonry infill walls. |
Copyright: | © 2023 by the authors; licensee MDPI, Basel, Switzerland. |
License: | Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original. |