0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Investigation of the influence of bed joint steel reinforcement on the load‐bearing capacity and deformability of walls made of AAC (subjected to vertical compression). Part 2 test of the wall connection zone

Auteur(s): ORCID
ORCID
Médium: article de revue
Langue(s): anglais
Publié dans: ce/papers, , n. 2, v. 6
Page(s): 95-101
DOI: 10.1002/cepa.1963
Abstrait:

This paper presents results from testing full‐scale walls made of autoclaved aerated concrete (AAC). A new type of reinforcement—steel mesh reinforcement protected against corrosion, was used in these tests. This paper is a second part of the paper and a continuation of previous tests. It presents the effect of reinforcement on the connection zone of perpendicular walls. The analysis was performed for load‐bearing capacity and crack resistance of the connection of perpendicular walls subjected to non‐uniform loading. The results were compared with the results from previous tests. The results were also analyzed and rules for using reinforcement in the connection zone of perpendicular walls were established.

Structurae ne peut pas vous offrir cette publication en texte intégral pour l'instant. Le texte intégral est accessible chez l'éditeur. DOI: 10.1002/cepa.1963.
  • Informations
    sur cette fiche
  • Reference-ID
    10740319
  • Publié(e) le:
    12.09.2023
  • Modifié(e) le:
    12.09.2023
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine