Impermeability Durability of SCC Reinforced with Fibrillated Polypropylene Fiber

Auteur(s):


Médium: article de revue
Langue(s): anglais
Publié dans: The Open Civil Engineering Journal, , n. 1, v. 9
Page(s): 159-166
DOI: 10.2174/1874149501509010159
Abstrait:

The paper studied the influences of the volume content and slenderness ratio of fibrillated polypropylene fiber on the impermeability durability of self-consolidating concrete (SCC) reinforced with the fibrillated polypropylene fiber, and proposed to use the modified relative permeability coefficient method to evaluate the water-resistant properties of SCC reinforced with the fiber. Also, the influence mechanism of the fiber on the permeability of the concrete has been analyzed according to the mercury injection test, scanning electronic microscope (SEM) observation and the basic principles of fracture mechanics. Results showed that: 1) the total porosity of SCC gradually increased with the increase in the fiber content; 2) the harmful porosity of SCC decreased firstly and then increased with the increase in the fiber content, while the harmful porosity increased with the increase in the fiber length; 3) when the reference mix proportion of SCC was kept constant, the fiber volume content was not more than 0.10 %, and the appropriate fiber length ranged from 12 to 15mm; 4) when the volume content is no more than 0.15%, the hardened SCC reinforced with fibrillated polypropylene fiber possessed good water impermeability gradation (>P12); the splitting strength and flexural tensile strength of the hardened SCC reinforced with fibrillated polypropylene fiber increased with the addition of the fiber content; the relative water penetration coefficient of the hardened SCC reinforced with fibrillated polypropylene fiber decreased with the addition of the fiber content firstly and then increased; the Coulomb value first increased smoothly (the maximum Coulomb value is less than 2000C, and low according to JTJ/T 193-2009 and ASTM C 1202), and then increased sharply.

Copyright: © 2016 X.B. He et al.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10175643
  • Publié(e) le:
    30.12.2018
  • Modifié(e) le:
    02.06.2021
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine