Experimental Investigation on Atomization and Dustfall Characteristics of Combined Nozzles for Shearer External Spray in Fully Mechanized Coal Mining Face
Auteur(s): |
Qian Wang
Ruixin Song Junpeng Wang Cuicui Xu Gang Zhou Jiayuan Wang |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Advances in Civil Engineering, janvier 2021, v. 2021 |
Page(s): | 1-11 |
DOI: | 10.1155/2021/9441355 |
Abstrait: |
To explore the dustfall effect of combined nozzles used in a fully mechanized mining face, Phase Doppler Interferometry (PDI) system was used to test 6 types of high-efficiency atomizer under 8 MPa. A new nozzle group of nozzles 2#, 3#, and 5# is selected by atomization experiment. The atomization experiment and field application test of the preferred nozzle are performed. The experiment and field application results show that, with the spray pressure of 8 MPa, when the distance in the nozzle group is 200 mm and the angle change is 10 degrees, the atomization effect is the best. Under the optimal parameters, the average dustfall rates of the entire and respirable dust are 81.82% and 79.96%, respectively, which are 23.49% and 20.75% higher than those of the traditional shearer. |
Copyright: | © Qian Wang et al. |
License: | Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original. |
2.93 MB
- Informations
sur cette fiche - Reference-ID
10646762 - Publié(e) le:
10.01.2022 - Modifié(e) le:
17.02.2022