Experimental Investigation on Atomization and Dustfall Characteristics of Combined Nozzles for Shearer External Spray in Fully Mechanized Coal Mining Face
Autor(en): |
Qian Wang
Ruixin Song Junpeng Wang Cuicui Xu Gang Zhou Jiayuan Wang |
---|---|
Medium: | Fachartikel |
Sprache(n): | Englisch |
Veröffentlicht in: | Advances in Civil Engineering, Januar 2021, v. 2021 |
Seite(n): | 1-11 |
DOI: | 10.1155/2021/9441355 |
Abstrakt: |
To explore the dustfall effect of combined nozzles used in a fully mechanized mining face, Phase Doppler Interferometry (PDI) system was used to test 6 types of high-efficiency atomizer under 8 MPa. A new nozzle group of nozzles 2#, 3#, and 5# is selected by atomization experiment. The atomization experiment and field application test of the preferred nozzle are performed. The experiment and field application results show that, with the spray pressure of 8 MPa, when the distance in the nozzle group is 200 mm and the angle change is 10 degrees, the atomization effect is the best. Under the optimal parameters, the average dustfall rates of the entire and respirable dust are 81.82% and 79.96%, respectively, which are 23.49% and 20.75% higher than those of the traditional shearer. |
Copyright: | © Qian Wang et al. |
Lizenz: | Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden. |
2.93 MB
- Über diese
Datenseite - Reference-ID
10646762 - Veröffentlicht am:
10.01.2022 - Geändert am:
17.02.2022