0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Experimental Investigation of Ductility in GFRP RC Beams by Confining the Compression Zone

Auteur(s):

ORCID
Médium: article de revue
Langue(s): anglais
Publié dans: Advances in Civil Engineering, , v. 2024
Page(s): 1-21
DOI: 10.1155/2024/4268615
Abstrait:

Nowadays, building structures in corrosive environments requires some considerations. Being lightweight, high tensile strength, and corrosion resistance are the features that make fiber-reinforced plastic (FRP) bars an alternative component for longitudinal steel reinforcement of concrete. On the other hand, the linear elastic behavior of FRP bars, alongside the brittle behavior of concrete, makes brittle members without considerable ductility. In this paper, the effect of compression region confinement with CFRP sheets on the FRP-reinforced concrete beams was experimentally investigated. Eight GFRP reinforced beams with 2 m length, including one reference beam and seven confined beams, were constructed and tested under a four-point bending test. Based on the type of confinement, specimens are categorized into four groups. Flexural behavior improvements, including load carry capacity, energy dissipation capacity, and ductility, were observed in at least one specimen of each confined group. According to the results, the specimen that was spirally confined with a 30 mm ribbon width and angle of 10° had the best total energy absorption up to about 110% improvement in comparison to the unconfined specimen. On the other hand, vertically confined specimens with 50 mm ribbon width showed the highest improvement in ductility indices and load carrying capacity up to 60% and 11% in comparison to unconfined specimens, respectively. Due to concrete compression zone fractures in flexural failure mode, the over-reinforce method is considered the design philosophy. Results indicate that regardless of the confinement type (discrete vertical, discrete spiral, or continuous spiral confinement), there is an optimal amount for width, blank space between ribbons, and depth of confinement to achieve the best flexural behavior.

Structurae ne peut pas vous offrir cette publication en texte intégral pour l'instant. Le texte intégral est accessible chez l'éditeur. DOI: 10.1155/2024/4268615.
  • Informations
    sur cette fiche
  • Reference-ID
    10786148
  • Publié(e) le:
    20.06.2024
  • Modifié(e) le:
    20.06.2024
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine