0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Experimental Investigation of Ductility in GFRP RC Beams by Confining the Compression Zone

Autor(en):

ORCID
Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Advances in Civil Engineering, , v. 2024
Seite(n): 1-21
DOI: 10.1155/2024/4268615
Abstrakt:

Nowadays, building structures in corrosive environments requires some considerations. Being lightweight, high tensile strength, and corrosion resistance are the features that make fiber-reinforced plastic (FRP) bars an alternative component for longitudinal steel reinforcement of concrete. On the other hand, the linear elastic behavior of FRP bars, alongside the brittle behavior of concrete, makes brittle members without considerable ductility. In this paper, the effect of compression region confinement with CFRP sheets on the FRP-reinforced concrete beams was experimentally investigated. Eight GFRP reinforced beams with 2 m length, including one reference beam and seven confined beams, were constructed and tested under a four-point bending test. Based on the type of confinement, specimens are categorized into four groups. Flexural behavior improvements, including load carry capacity, energy dissipation capacity, and ductility, were observed in at least one specimen of each confined group. According to the results, the specimen that was spirally confined with a 30 mm ribbon width and angle of 10° had the best total energy absorption up to about 110% improvement in comparison to the unconfined specimen. On the other hand, vertically confined specimens with 50 mm ribbon width showed the highest improvement in ductility indices and load carrying capacity up to 60% and 11% in comparison to unconfined specimens, respectively. Due to concrete compression zone fractures in flexural failure mode, the over-reinforce method is considered the design philosophy. Results indicate that regardless of the confinement type (discrete vertical, discrete spiral, or continuous spiral confinement), there is an optimal amount for width, blank space between ribbons, and depth of confinement to achieve the best flexural behavior.

Structurae kann Ihnen derzeit diese Veröffentlichung nicht im Volltext zur Verfügung stellen. Der Volltext ist beim Verlag erhältlich über die DOI: 10.1155/2024/4268615.
  • Über diese
    Datenseite
  • Reference-ID
    10786148
  • Veröffentlicht am:
    20.06.2024
  • Geändert am:
    20.06.2024
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine