Abstrait: |
This paper presents the velocity wave of concrete spun piles with welded splice. The stress wave velocity was recorded using Pile Integrity Test. Two specimens were prepared in the experiment. The first sample was prepared visually no gap between the two end-plates of connected piles, while the second specimen was prepared by inserting 5mm thick steel plate into the splice to create a gap in its connection. The results show that a spike of reflecting stress wave still develops at the splice with and without gap, regardless the splice was welded in full circle. The relatively high spikes of reflecting waves at pile toe are noticed for both specimens with and without gaps. It shows that the full welded splice able to transfer stress wave velocity. A good quality of welded splice can be indicated by the reflecting wave at the pile toe, regardless the reflecting wave development at the splice. |
Copyright: | © All right reserved 2022. Civil Engineering Dimension |
License: | Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original. |
0.57 MB
- Informations
sur cette fiche - Reference-ID
10699684 - Publié(e) le:
10.12.2022 - Modifié(e) le:
15.02.2023