This paper evaluates the seismic performance of an existing reinforced concrete (RC) building after strengthening by using the nonlinear static analysis procedure (NSP). The comprehension gained fr...
Lire plus

Détails bibliographiques

Auteur(s): (FSE CONSULTANT CO., LTD.)
Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022
Publié dans:
Page(s): 387-394 Nombre total de pages (du PDF): 8
Page(s): 387-394
Nombre total de pages (du PDF): 8
DOI: 10.2749/prague.2022.0387
Abstrait:

This paper evaluates the seismic performance of an existing reinforced concrete (RC) building after strengthening by using the nonlinear static analysis procedure (NSP). The comprehension gained from such an evaluation can be used to propose effective control measures or strengthening techniques for other existing low-rise RC buildings. In this case study, the approach was applied to an existing 4-storey banquet hall with a basement in Bangkok, Thailand. During construction in 1998, the 3rd floor slab was partly demolished. Strengthening was then carried out by adding new RC columns. As the building was constructed in 1998, the structure no longer meets the new Thai regulation. As a result, the building may have had significant deficiencies, and an assessment had to be conducted according to the Thai Ministerial Regulation B.E. 2564 (2021) and ASCE 41-17. A seismic safety evaluation was applied after the building had been strengthened by using the NSP, which was performed by using a software program. The results showed that, after strengthening, it complied with the regulation and standards. Therefore, it was proven that this building is able to resist the selected seismic forces along with other loads to provide sufficient performance.

Mots-clé:
renforcement
Copyright: © 2022 International Association for Bridge and Structural Engineering (IABSE)
License:

Cette oeuvre ne peut être utilisée sans la permission de l'auteur ou détenteur des droits.