Ring Rail Line – Protection Structures Against Aggressive Fluids

 Ring Rail Line – Protection Structures Against Aggressive Fluids
Auteur(s): , ,
Présenté pendant IABSE Workshop: Safety, Failures and Robustness of Large Structures, Helsinki, Finland, 14-15 February 2013, publié dans , pp. 186-192
DOI: 10.2749/222137813807018863
Prix: € 25,00 incl. TVA pour document PDF  
AJOUTER AU PANIER
Télécharger l'aperçu (fichier PDF) 0.5 MB

During the excavations of railway tunnel of Ring Rail Line ground water leakages containing ad-verse compounds were found under the airport area. The investigations showed that ground water at a mi...
Lire plus

Détails bibliographiques

Auteur(s):


Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Workshop: Safety, Failures and Robustness of Large Structures, Helsinki, Finland, 14-15 February 2013
Publié dans:
Page(s): 186-192 Nombre total de pages (du PDF): 7
Page(s): 186-192
Nombre total de pages (du PDF): 7
Année: 2013
DOI: 10.2749/222137813807018863
Abstrait:

During the excavations of railway tunnel of Ring Rail Line ground water leakages containing ad-verse compounds were found under the airport area. The investigations showed that ground water at a minimum pH under 5 is acidic and contains antifreeze agents as ethylene and propylene glycols which have been used decades in aviation. In aerobic conditions the glycol based fluid forms alco-hols and organic acids, most relevant of them acetic acid and propionic acid. The fluid is a nutrient for microbes and enables their growth in a tunnel. The microbe growth forms also distinctive odour, which is undesirable at underground railway used by passengers.

To isolate harmful aggressive leakages protection structures were designed for all tunnel sections and station areas where adverse substances were detected. Leakage has been found to be corrosive to steel structures and erode to cement-containing structures so polyethane membranes were de-signed to install around the railway tunnel structures and all materials which can be in contact with glycol based fluids were chosen for aggressive environments.

Mots-clé:
membrane mouillages acides croissance des microbes