Repair and Strengthening of Reinforced Concrete Slab-Column Connections
|
Détails bibliographiques
Auteur(s): |
Widianto
Oguzhan Bayrak James Jirsa |
||||
---|---|---|---|---|---|
Médium: | papier de conférence | ||||
Langue(s): | anglais | ||||
Conférence: | 17th IABSE Congress: Creating and Renewing Urban Structures – Tall Buildings, Bridges and Infrastructure, Chicago, USA, 17-19 September 2008 | ||||
Publié dans: | IABSE Congress Chicago 2008 | ||||
|
|||||
Page(s): | 84-85 | ||||
Nombre total de pages (du PDF): | 8 | ||||
Année: | 2008 | ||||
DOI: | 10.2749/222137908796291886 | ||||
Abstrait: |
Seven 2/3-scale interior slab-column connections were tested to quantify the effects of earthquake damage, and the efficiency of various rehabilitation techniques on repairing seismic damaged slab- column connections and improving the two-way shear strength of deficient connections. Three alternatives for rehabilitating slab-column connections were experimentally evaluated: (i) installation of steel collars, (ii) installation of external Carbon Fiber Reinforced Polymers (CFRP) stirrups, and (iii) application of well-anchored CFRP sheets. All three techniques increased the connection strength and improved the residual capacity after punching failure. |
||||
Mots-clé: |
renforcement mouillages
|