0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Properly designed expansion joint to ensure successful seismically Isolated Structures

 Properly designed expansion joint to ensure successful seismically Isolated Structures
Auteur(s): , , ,
Présenté pendant IABSE Congress: Resilient technologies for sustainable infrastructure, Christchurch, New Zealand, 3-5 February 2021, publié dans , pp. 479-486
DOI: 10.2749/christchurch.2021.0479
Prix: € 25,00 incl. TVA pour document PDF  
AJOUTER AU PANIER
Télécharger l'aperçu (fichier PDF) 0.46 MB

Seismic isolation system has become one of the most efficient approaches chosen by design engineers for having better seismic performance and cost-efficiency for structures located in high seismici...
Lire plus

Détails bibliographiques

Auteur(s): (Bandung Institute of Technology, Bandung, Indonesia)
(Freyssinet Total Technology, Jakarta, Indonesia)
(Freyssinet Total Technology, Jakarta, Indonesia)
(Delta Global Struktur, Jakarta, Indonesia)
Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Congress: Resilient technologies for sustainable infrastructure, Christchurch, New Zealand, 3-5 February 2021
Publié dans:
Page(s): 479-486 Nombre total de pages (du PDF): 8
Page(s): 479-486
Nombre total de pages (du PDF): 8
DOI: 10.2749/christchurch.2021.0479
Abstrait:

Seismic isolation system has become one of the most efficient approaches chosen by design engineers for having better seismic performance and cost-efficiency for structures located in high seismicity area. For bridges, the seismic isolation system is usually done by replacing the conventional bearings (pot or spherical bearings) with seismic isolator bearings (rubber isolator bearings or pendulum bearings). In general, only these isolator bearings that will be the focus of considerations during design phase. It is commonly forgotten that the seismic isolation system shall be also coupled with properly installed seismic expansion joint that can accommodate large movements on the bridge deck due to isolation effect of the seismic system. Improperly designed expansion joint is usually shown by the use of small non-seismic joint that leads to very narrow provided gaps in between the concrete deck and its adjacent structure. These gaps are not able to accommodate large movements on the deck of a seismically isolated bridge. Collisions or poundings during seismic event are inevitable. This leads to dysfunctionality of seismic isolation system, and in the worst case it may generate excessive impact forces that will result to undesired performance level and damages on the structures.