Load-carrying capacity of RC members in the viaducts of Railway where ASR occurred

 Load-carrying capacity of RC members in the viaducts of Railway where ASR occurred
Auteur(s): ,
Présenté pendant IABSE Congress: The Evolving Metropolis, New York, NY, USA, 4-6 September 2019, publié dans , pp. 1457-1463
DOI: 10.2749/newyork.2019.1457
Prix: € 25,00 incl. TVA pour document PDF  
AJOUTER AU PANIER
Télécharger l'aperçu (fichier PDF) 0.16 MB

In Japan, measures against ASR have been started since the late 1980s, but it is no exaggeration to say that all buildings built before that may be affected by ASR. Deterioration and damage due to ...
Lire plus

Détails bibliographiques

Auteur(s): (East Japan Railway Company)
(East Japan Railway Company)
Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Congress: The Evolving Metropolis, New York, NY, USA, 4-6 September 2019
Publié dans:
Page(s): 1457-1463 Nombre total de pages (du PDF): 7
Page(s): 1457-1463
Nombre total de pages (du PDF): 7
DOI: 10.2749/newyork.2019.1457
Abstrait:

In Japan, measures against ASR have been started since the late 1980s, but it is no exaggeration to say that all buildings built before that may be affected by ASR. Deterioration and damage due to ASR are remarkable in the section from around TsubameSanjo Station on the Joetsu Shinkansen operating in East Japan Railway Company to around Niigata Station, and there are situations where maintenance management is difficult. Currently, if there are major defects in regular inspections, we will carry out surface treatment etc., but we are starting to study how to prevent the ingress of water at the stage of minor defects in order to prevent the progression of ASR. When waterproofing the surface of a structure in which a crack or the like is generated by ASR, the effects of water blocking effect and reduction of the amount of water in concrete are not well known. In this report, RC slab members exposed and stored for about 15 years (about 40 years after completion) were used as RC beam specimens, and were dried to some extent on the assumption that moisture was blocked, and a loading test was performed. As a result of the loading test, the maximum strength of the RC beam specimen was larger than the calculated shear strength. From this result, it is considered that the damage level of the current ASR does not have the effect of reducing the shear resistance so much.