0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Hutt River pipeline bridge spanning across the Wellington fault

 Hutt River pipeline bridge spanning across the Wellington fault
Auteur(s): , ,
Présenté pendant IABSE Congress: Resilient technologies for sustainable infrastructure, Christchurch, New Zealand, 3-5 February 2021, publié dans , pp. 513-520
DOI: 10.2749/christchurch.2021.0513
Prix: € 25,00 incl. TVA pour document PDF  
AJOUTER AU PANIER
Télécharger l'aperçu (fichier PDF) 0.2 MB

This project originates from the need to provide seismic resilient solution for water supply to Wellington and Porirua. With other factors influencing the design, the pipeline crossing must withsta...
Lire plus

Détails bibliographiques

Auteur(s): (GHD)
(GHD)
(GHD)
Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Congress: Resilient technologies for sustainable infrastructure, Christchurch, New Zealand, 3-5 February 2021
Publié dans:
Page(s): 513-520 Nombre total de pages (du PDF): 8
Page(s): 513-520
Nombre total de pages (du PDF): 8
DOI: 10.2749/christchurch.2021.0513
Abstrait:

This project originates from the need to provide seismic resilient solution for water supply to Wellington and Porirua. With other factors influencing the design, the pipeline crossing must withstand seismic loads including the rupture event of the Wellington Fault with movement of +/-6.5 m parallel to the river stream

The option study for the pipeline crossing concluded on using a bridge structure spanning the river and the geological Fault. This network arch bridge structure selected is provided with enough movement capacity to withstand the effects of the fault rupture movement without failure.

The length of the bridge structure is defined so to match the differential rotations between the supports to the allowable limits for the pipeline flex joints. To resist these seismic effects, the structure is provided with seismic restrainers that, at the same time as supporting the seismic load, provide enough rotation capability to accommodate movements on the foundations due to the Fault’s ruptureevent.

Mots-clé:
conception sismique pont en arc câble