0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

A Full-scale Experiment on Vibration Mitigation of Stay Cable

Auteur(s):



Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Symposium: Metropolitan Habitats and Infrastructure, Shanghai, China, 22-24 September 2004
Publié dans:
Page(s): 154-155
Année: 2004
DOI: 10.2749/222137804796291520
Abstrait: Mechanical dampers are often installed near to anchorages of stay cables for mitigating vibrations due to wind or wind/rain. However, the optimal damping estimated by a linear theory is hard to be obtained and an efficiency factor between the designed damping and the practical one has to be considered for design. In this study, experiments of cable-damper system were conducted by using a 215 meters long full-scale stay cable. 7 types of mechanical dampers, including oil damper, viscous damper and MR damper, were adopted. The experimental results show that an inner type damper provided an additional damping (log decrement) 0.013, other outer type dampers provided additional damping larger than 0.030. Based on the experimental results, the authors suggest that the efficiency factor should be 0.3 for an inner type damper, and 0.5 for an outer type damper. The nonlinear design theory was also preliminarily studied.
  • Informations
    sur cette fiche
  • Reference-ID
    10295272
  • Publié(e) le:
    06.02.2019
  • Modifié(e) le:
    29.03.2021
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine