0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Experimental fire performance of unloaded stay-cables for bridge infrastructure

 Experimental fire performance of unloaded stay-cables for bridge infrastructure
Auteur(s): , ORCID, ORCID
Présenté pendant IABSE Congress: Resilient technologies for sustainable infrastructure, Christchurch, New Zealand, 3-5 February 2021, publié dans , pp. 710-716
DOI: 10.2749/christchurch.2021.0710
Prix: € 25,00 incl. TVA pour document PDF  
AJOUTER AU PANIER
Télécharger l'aperçu (fichier PDF) 0.25 MB

The performance-based fire protection design of cable-supported bridge structures is becoming more common as stakeholders desire more resilient infrastructure. Currently, there exist significant kn...
Lire plus

Détails bibliographiques

Auteur(s): (York University, Toronto, Canada)
ORCID (York University, Toronto, Canada)
ORCID (ARUP, Manchester, UK)
Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Congress: Resilient technologies for sustainable infrastructure, Christchurch, New Zealand, 3-5 February 2021
Publié dans:
Page(s): 710-716 Nombre total de pages (du PDF): 7
Page(s): 710-716
Nombre total de pages (du PDF): 7
DOI: 10.2749/christchurch.2021.0710
Abstrait:

The performance-based fire protection design of cable-supported bridge structures is becoming more common as stakeholders desire more resilient infrastructure. Currently, there exist significant knowledge gaps regarding the fire performance of structural steel cables. The study herein examines the thermal response of several varieties of unloaded steel-stay cables during exposure to a non- standard methanol pool fire. Eight stay-cables varying in configuration (locked and spiral coil), diameter (22,6 mm – 140 mm), and alloy (stainless and galvanized steel) are supported above a 0,6 m x 0,48 m methanol pool fire for duration of approximately 35 minutes. Thermocouples are instrumented at the top, core, and soffit of the cable structure at four different cross-sections to monitor heat transfer during and post-fire. Digital image correlation (DIC) is applied in conjunction with narrow-spectrum illumination to monitor the cable surface without optical interference from flames. Global and individual wire strains are calculated from the DIC analysis to quantify thermal expansion. Temperature data throughout the cable structure presents insight into the heat transfer of steel wire-rope elements. Preliminary results indicate individual wire thermal expansion is similar to that of the global cable structure and that interaction between adjacent wires may limit individual wire expansion. This implies thermal expansion may not be consistent until the cable cross-section is of uniform temperature.