Dynamic behavior of an innovative replaceable pier structure under lateral impact loadings
|
Détails bibliographiques
Auteur(s): |
Chengdong Liu
(Tongji University)
Junjie Wang (Tongji University) Yanchen Song (Tongji University) |
||||
---|---|---|---|---|---|
Médium: | papier de conférence | ||||
Langue(s): | anglais | ||||
Conférence: | IABSE Congress: The Evolving Metropolis, New York, NY, USA, 4-6 September 2019 | ||||
Publié dans: | The Evolving Metropolis | ||||
|
|||||
Page(s): | 453-458 | ||||
Nombre total de pages (du PDF): | 6 | ||||
DOI: | 10.2749/newyork.2019.0453 | ||||
Abstrait: |
In order to improve the repair efficiency of bridge piers subjected to vehicle and ship collisions, an innovative replaceable pier structure based on flange connection and PBL shear connector was proposed. The finite element model of the replaceable pier and the traditional pier were developed and then validated through experimental test results. The behavior of replaceable pier and connection joint under lateral impact loading was studied based on numerical simulations. Compared with the traditional pier, it shows that the ability of new replaceable pier to resist impact loading is more favorable, and the connection component of new replaceable pier is repeatable. |