In recent years, the rapid development of super tall buildings has become a frontier in civil engineering. Subjected to service level earthquakes, all of the plastic energy dissipation components a...
Lire plus

Détails bibliographiques

Auteur(s): (Tsinghua University, Beijing, China)
(Tsinghua University, Beijing, China)
(Hefei University of Technology, Hefei, China)
(Tsinghua University, Beijing, China)
Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Congress: Challenges in Design and Construction of an Innovative and Sustainable Built Environment, Stockholm, Sweden, 21-23 September 2016
Publié dans:
Page(s): 991-998 Nombre total de pages (du PDF): 8
Page(s): 991-998
Nombre total de pages (du PDF): 8
Année: 2016
DOI: 10.2749/stockholm.2016.0978
Abstrait:

In recent years, the rapid development of super tall buildings has become a frontier in civil engineering. Subjected to service level earthquakes, all of the plastic energy dissipation components are still in the elastic stage, and will not dissipate energy. In this situation, the story acceleration will be magnified several times, resulting in the comfort problem and causing the damage of contents in the building and other non-structural components. It will not only bring serious economic losses, but also affect the normal function of the building. Therefore, corresponding measures should be proposed to reduce the story acceleration of super tall buildings under service level earthquakes. A simplified analytical model for super tall buildings based on the flexural-shear coupling beam model is developed in this work. Based on the simplified model with a super TMD on the top of the building, the control effect of TMD on the story acceleration is studied by time history analysis. The optimal frequency of TMD is determined through parametric discussion. The outcome of this study can provide some references for the engineering design and vibration reduction of super tall buildings.