0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Defect detection in strand wires within the anchorage area of high tensioned cables

 Defect detection in strand wires within the anchorage area of high tensioned cables
Auteur(s): ,
Présenté pendant IABSE Conference: Structural Engineering: Providing Solutions to Global Challenges, Geneva, Switzerland, September 2015, publié dans , pp. 1408-1411
DOI: 10.2749/222137815818358727
Prix: € 25,00 incl. TVA pour document PDF  
AJOUTER AU PANIER
Télécharger l'aperçu (fichier PDF) 0.07 MB

Assessment of cables of cable supported structures is complicated there these elements are often difficult to inspect visually. Owners of these kind of structures are facing a lack of information o...
Lire plus

Détails bibliographiques

Auteur(s): (Advitam, Rueil Malmaison, France)
(Advitam, Rueil Malmaison, France)
Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Conference: Structural Engineering: Providing Solutions to Global Challenges, Geneva, Switzerland, September 2015
Publié dans:
Page(s): 1408-1411 Nombre total de pages (du PDF): 4
Page(s): 1408-1411
Nombre total de pages (du PDF): 4
Année: 2015
DOI: 10.2749/222137815818358727
Abstrait:

Assessment of cables of cable supported structures is complicated there these elements are often difficult to inspect visually. Owners of these kind of structures are facing a lack of information on these key elements of their structures.

This paper presents a new promising technology that can provide a solution for this problem by providing information on the condition of the cables inside the anchorage area.

In general the anchorage areas of cables is the most vulnerable part of cables due to water ingress, lower protection of the wires and fatigue issues. Typical defects in these areas are corrosion, cross section loss and wire breaks.

The development of this technology over the past years in cooperation with the French National Laboratory IFSTTAR has resulted in a fully proven and operational tool that recently demonstrated its value on a full scale application on one of world’s largest stay Cable Bridge where it successfully assessed the condition of the cables behind the bottom anchorage. Over 80 000 wires have been inspected for defects on this project. Other structural owners have acknowledged the value of the technology by testing their cable anchorages.

The technology is based on Ultrasonic guided waves principle transmitted along a single wire of a 7 x 5 wire strand. This paper explains the principle of the technology, shows how it can be deployed on site, and provide feedback from lab tests and real measurement on site.