-
Živanović, S. / Pavic, A. / Reynolds, P. (2005): Vibration serviceability of footbridges under human-induced excitation: a literature review. Dans: Journal of Sound and Vibration, v. 279, n. 1-2 (janvier 2005).
https://doi.org/10.1016/j.jsv.2004.01.019
-
Jones, C. A. / Reynolds, P. / Pavic, A. (2011): Vibration serviceability of stadia structures subjected to dynamic crowd loads: A literature review. Dans: Journal of Sound and Vibration, v. 330, n. 8 (avril 2011).
https://doi.org/10.1016/j.jsv.2010.10.032
-
Harrison, R. E. / Yao, S. / Wright, J. R. / Pavic, A. / Reynolds, P. (2008): Human Jumping and Bobbing Forces on Flexible Structures: Effect of Structural Properties. Dans: Journal of Engineering Mechanics (ASCE), v. 134, n. 8 (août 2008).
https://doi.org/10.1061/(asce)0733-9399(2008)134:8(663)
-
Pavic, A. / Živanović, S. / Reynolds, P. (2005): Errors in Numerical Solution of Equation of Motion of Lightly Damped Sdof System Near Resonance. Dans: International Journal of Structural Stability and Dynamics, v. 5, n. 1 (mars 2005).
https://doi.org/10.1142/s0219455405001477
-
Hudson, M. J. / Reynolds, P. / Nyawako, D. (2011): Efficient Design of Floor Structures Using Active Vibration Control. Présenté pendant: Structures Congress 2011, Las Vegas, Nevada, April 14-16, 2011.
https://doi.org/10.1061/41171(401)35
-
Gutteridge, A. / Hoti, A. / Reynolds, P. (2003): The walled town of Dyrrachium (Durres): new light on the early defences. Dans: Journal of Roman Archeology, v. 16 ( 2003).
https://doi.org/10.1017/s1047759400013192
-
Hudson, E. J. / Reynolds, P. (2014): Implications of structural design on the effectiveness of active vibration control of floor structures. Dans: Structural Control and Health Monitoring, v. 21, n. 5 (mai 2014).
https://doi.org/10.1002/stc.1595
-
Pavic, A. / Reynolds, P. / Waldron, P. (2002): Modal testing and FE model correlation and updating of a long-span prestressed concrete floor. Dans: Proceedings of the Institution of Civil Engineers - Structures and Buildings, v. 152, n. 2 (mai 2002).
https://doi.org/10.1680/stbu.2002.152.2.97
-
Pavic, A. / Armitage, T. / Reynolds, P. / Wright, J. (2002): Methodology for modal testing of the Millennium Bridge, London. Dans: Proceedings of the Institution of Civil Engineers - Structures and Buildings, v. 152, n. 2 (mai 2002).
https://doi.org/10.1680/stbu.2002.152.2.111
-
Reynolds, P. / Pavic, A. / Ibrahim, Z. (2004): A remote monitoring system for stadia dynamics. Dans: Proceedings of the Institution of Civil Engineers - Structures and Buildings, v. 157, n. 6 ( 2004).
https://doi.org/10.1680/stbu.2004.157.6.385
-
Yao, S. / Wright, J. / Yu, C.-H. / Pavic, A. / Reynolds, P. (2005): Human-induced swaying forces on flexible structures. Dans: Proceedings of the Institution of Civil Engineers - Structures and Buildings, v. 158, n. 2 (avril 2005).
https://doi.org/10.1680/stbu.2005.158.2.109
-
Hudson, M. J. / Reynolds, P. (2012): Implementation considerations for active vibration control in the design of floor structures. Dans: Engineering Structures, v. 44 (novembre 2012).
https://doi.org/10.1016/j.engstruct.2012.05.034
-
Díaz, I. M. / Reynolds, P. (2009): Robust saturated control of human-induced floor vibrations via a proof-mass actuator. Dans: Smart Materials and Structures, v. 18, n. 12 (décembre 2009).
https://doi.org/10.1088/0964-1726/18/12/125024
-
Nyawako, D. / Reynolds, P. (2009): Response-dependent velocity feedback control for mitigation of human-induced floor vibrations. Dans: Smart Materials and Structures, v. 18, n. 7 (juillet 2009).
https://doi.org/10.1088/0964-1726/18/7/075002
-
Miskovic, Z. / Pavic, A. / Reynolds, P. (2009): Effects of full-height nonstructural partitions on modal properties of two nominally identical building floors. Dans: Canadian Journal of Civil Engineering / Revue canadienne de génie civil, v. 36, n. 7 (juillet 2009).
https://doi.org/10.1139/l09-055
-
Pavic, A. / Miskovic, Z. / Reynolds, P. (2007): Modal Testing and Finite-Element Model Updating of a Lively Open-Plan Composite Building Floor. Dans: Journal of Structural Engineering (ASCE), v. 133, n. 4 (avril 2007).
https://doi.org/10.1061/(asce)0733-9445(2007)133:4(550)
-
Reynolds, P. / Pavic, A. (2003): Effects of False Floors on Vibration Serviceability of Building Floors. II: Response to Pedestrian Excitation. Dans: Journal of Performance of Constructed Facilities (ASCE), v. 17, n. 2 (mai 2003).
https://doi.org/10.1061/(asce)0887-3828(2003)17:2(87)
-
Reynolds, P. / Pavic, A. (2003): Effects of False Floors on Vibration Serviceability of Building Floors. I: Modal Properties. Dans: Journal of Performance of Constructed Facilities (ASCE), v. 17, n. 2 (mai 2003).
https://doi.org/10.1061/(asce)0887-3828(2003)17:2(75)
-
Yao, S. / Wright, J. R. / Pavic, A. / Reynolds, P. (2004): Experimental study of human-induced dynamic forces due to bouncing on a perceptibly moving structure. Dans: Canadian Journal of Civil Engineering / Revue canadienne de génie civil, v. 31, n. 6 (décembre 2004).
https://doi.org/10.1139/l04-081
-
Živanović, S. / Pavic, A. / Reynolds, P. (2005): Human–structure dynamic interaction in footbridges. Dans: Proceedings of the Institution of Civil Engineers - Bridge Engineering, v. 158, n. 4 (décembre 2005).
https://doi.org/10.1680/bren.2005.158.4.165
-
Pavic, A. / Willford, Michael / Reynolds, P. / Wright, J. (2002): Key results of modal testing of the Millennium bridge, London. Présenté pendant: Footbridge 2002, Paris, 20-22.11.2002.