Uplift Behaviour of External Fibre-Reinforced Polymer Wrapping on RC Piles in Dry and Submerged Sandy Soil

Auteur(s):

ORCID
Médium: article de revue
Langue(s): anglais
Publié dans: Buildings, , n. 3, v. 13
Page(s): 778
DOI: 10.3390/buildings13030778
Abstrait:

The sudden occurrence of an earthquake induces a liquefaction effect on foundation soil, which causes a substantial increase in the uplift pressure acting on piles and causes structural damage to superstructures. This forms the basis of the necessity of experimenting with the behaviour of piles subjected to uplift loads and predicting their load-carrying capacity or resistance. Fibre-reinforced polymer (FRP) wraps are widely used for strengthening and retrofitting piles subjected to damage. The current study is aimed at determining the uplift load-carrying capacity or resistance of piles wrapped with basalt fibre-reinforced polymer (BFRP) and glass fibre-reinforced polymer (GFRP) sheets by experiment. Preliminary tests were conducted to identify the influence of BFRP and GFRP wraps on the mechanical strength properties of concrete. The mechanical strength of the specimen with the double wrapping of basalt and glass fibres in the perpendicular direction outperformed all other specimens. Moreover, the piles were wrapped with laminates and experimented on for their uplift capacity in dry and submerged conditions. The results indicate a considerable improvement in the uplift resistance of the piles compared with the unconfined piles. The BFRP and GFRP wraps improved the uplift resistance of the piles by 35.56% and 15.56%, respectively, higher than the unconfined pile for dry conditions. The angle of the interfacial friction in dry and submerged states was observed to be the maximum for the perpendicular direction for both of the FRP wraps, and the failure modes were compared. The simulated model showed a significant correctness for determining the uplift resistance of FRP-wrapped piles in dry and submerged states. The degree of agreement in the dry condition for the experimental results and finite element method was more than 94% for all fibre wraps.

Copyright: © 2023 by the authors; licensee MDPI, Basel, Switzerland.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10712071
  • Publié(e) le:
    21.03.2023
  • Modifié(e) le:
    10.05.2023
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine