Abstrait:

The concrete-faced rockfill dam (CFRD) has been widely constructed worldwide, and the reliability of the concrete panels, the most important containment structure, is critical to the safety of the CFRDs and downstream communities. Several practical projects show that concrete slab cracking usually occurs during the water storage period, which can be attributed to the rapid increase of hydrostatic pressure and uneven settlement of the dam body. In this paper, a time-dependent reliability analysis method considering the fuzziness of the failure criterion is presented to assess the slab cracking risk of the Houziyan CFRD during the water storage period. Based on the observed deformation, the material parameters are calibrated to ensure the fidelity of the numerical simulation. Based on the Drucker–Prager yield criterion and tensile strength criterion, the response surface method is utilized to construct the performance functions at different moments, and then the time-dependent reliability analysis considering the fuzzy failure criteria is implemented for the concrete slab. The case study of the Houziyan CFRD shows that, during the initial period of water storage, the reliability index of the concrete slab decreases with the rise of the water level. With a stable water level, the probability of cracking of the concrete slab slowly decreases as the deformation of the dam body and slab tend to be coordinated. Especially, considering the fuzziness of the failure criteria, the reliability index decreased by about 2%, indicating that the proposed evaluation method is biased toward safety. The method proposed in this paper can reflect the evolution law of concrete slab reliability with the operating environment and provides a new approach to evaluate the performance of the concrete slab during the water storage period.

Structurae ne peut pas vous offrir cette publication en texte intégral pour l'instant. Le texte intégral est accessible chez l'éditeur. DOI: 10.1155/2024/1150405.
  • Informations
    sur cette fiche
  • Reference-ID
    10771586
  • Publié(e) le:
    29.04.2024
  • Modifié(e) le:
    29.04.2024
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine