0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Technical Note: Unbraced Length Requirements for Steel Special Cantilever Column Systems

Auteur(s):

Médium: article de revue
Langue(s): anglais
Publié dans: Engineering Journal, , n. 4, v. 57
Page(s): 243-245
DOI: 10.62913/engj.v57i4.1169
Abstrait:

AISC Seismic Provisions Section E6.4b for steel special cantilever column systems (SCCS) requires clarification based on inquiries to the AISC Steel Solution Center. In the 2016 edition, it is unclear if bracing is required for all special cantilever columns or for columns with unbraced lengths that exceed the maximum beam brace spacing of Lb per Section D1.2a for moderately ductile members. Instead of using Equation D1-2, which is applicable to I-shaped beams only, equations for SCCS columns have been derived for both I-shaped members and rectangular HSS or box-shaped members. The proposed revision provides specific situations when bracing is required.

Structurae ne peut pas vous offrir cette publication en texte intégral pour l'instant. Le texte intégral est accessible chez l'éditeur. DOI: 10.62913/engj.v57i4.1169.