0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Study on Structural Service Performance of Heavy-Haul Railway Tunnel with Voided Base

Auteur(s):



Médium: article de revue
Langue(s): anglais
Publié dans: Advances in Civil Engineering, , v. 2018
Page(s): 1-12
DOI: 10.1155/2018/3510979
Abstrait:

The structural design of heavy-haul railway tunnels still follows the design method of ordinary railway tunnels. Most of them do not take into account the influence of large axle load of 30 t or more, let alone such problems as void of surrounding rock under long-term dynamic loads. In order to analyze the dynamic response of heavy-haul railway tunnels under long-term reciprocating cyclic dynamic loads, considering the factors such as axle load of vehicle body, unsprung mass, and track irregularity, the vibration load time-history curve of heavy-haul railway trains is determined, the three-dimensional dynamics coupling model of dynamic load-tunnel-surrounding rock is established, and the fatigue life of the structure under different void conditions is analyzed based on the S-N curve of concrete. According to the study, the loading, unloading, and vibration caused by train passing will lead to fluctuations in the vertical displacement response of the monitoring point. The peaks and valleys of the response time-history curve correspond to the effect of the train wheels rolling through. When the void is 6 m wide and 10 cm thick, the vertical displacement of the inverted arch is increased by about 9 times, the peak velocity of the inverted arch is increased by about 3.8 times, and the maximum principal stress is increased by about 47.3%, compared with the condition without void. With the same void thickness, the vertical displacement and velocity curves of the inverted arch vary significantly with the increase of the void width. The width of the base void has a significant effect on the fatigue life of the structure of heavy-haul railway tunnels. Based on the operation requirement of 100-year service life, the ultimate void width is 2 m.

Copyright: © 2018 Zhiqiang Zhang et al.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10176285
  • Publié(e) le:
    30.11.2018
  • Modifié(e) le:
    02.06.2021
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine