Study on Shock-Absorbing Effect of a Double-Story Isolation Structure Considering Soil–Structure Interaction
Auteur(s): |
Liang Gao
Dewen Liu Min Lei Yong Ding Shian Mu |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Buildings, 26 octobre 2023, n. 11, v. 13 |
Page(s): | 2677 |
DOI: | 10.3390/buildings13112677 |
Abstrait: |
The double-story isolation structure is a novel development based on the mid-story isolation structure. To accurately reflect the seismic response of the double-story isolation structure, this study considers a dynamic elastoplastic analysis model that incorporates soil–structure interaction (SSI). Comparative models of a base-fixed structure and a mid-story isolation structure are also established. The results indicate that the double-story isolation structure has a longer structural period compared to the mid-story isolation structure. Furthermore, the structural period increases as the soil softens and the structure becomes more flexible. When considering SSI on hard soil versus not considering SSI, the double-story isolation structure exhibits smaller base shear, story force, inter-story displacement, maximum acceleration of the top floor, and displacement of the upper isolation layer, indicating the significant shock-absorbing effect of the double-story isolation structure. However, when SSI is considered on soft soil, the shock-absorbing effect of the isolation structure diminishes, and the effectiveness of the double-story isolation structure may not necessarily surpass that of the mid-story isolation structure. In all three soil conditions, the compressive stresses of the isolation bearings in the upper isolation layer of the double-story isolation structure were lower than those in the isolation bearings of the base isolation layer. Additionally, the double-story isolation structure demonstrates reduced compressive stress in the isolation bearings, fewer plastic hinges in the frame, and less stress damage compared to the mid-story isolation structure. Consequently, the risk of overturning damage in the double-story isolation structure is significantly reduced compared to the mid-story isolation structure. The effect of soft ground on structures can be highly detrimental, which should be paid more attention to during the design process. This study offers valuable insights for future research on double-story isolation systems and serves as a reference for the development of high-performance building structures in the future. |
Copyright: | © 2023 by the authors; licensee MDPI, Basel, Switzerland. |
License: | Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original. |
14.62 MB
- Informations
sur cette fiche - Reference-ID
10744358 - Publié(e) le:
28.10.2023 - Modifié(e) le:
07.02.2024