Static Test Verification on Retrofitting Method for On-service Transmission Tower

Auteur(s):




Médium: article de revue
Langue(s): anglais
Publié dans: Journal of Physics: Conference Series, , n. 1, v. 2503
Page(s): 012031
DOI: 10.1088/1742-6596/2503/1/012031
Abstrait:

Retrofitting methods for transmission tower on-service conditions should avoid punching and welding. This paper presents a non-destructive retrofitting method, the T-shaped composite angles method, to meet the demand. The original angle was combined with retrofitting components by V-shaped clamps. Both numerical analysis and static loading test were carried out to verify the effectiveness of this retrofitting method. The test results show that compared with the lateral stiffness of the original transmission tower segment, the stiffness of the reinforced one increased. The load-bearing capacity of the reinforced transmission tower segment almost doubled that before the reinforcement. The proposed retrofitting method is non-destructive and effective.

Structurae ne peut pas vous offrir cette publication en texte intégral pour l'instant. Le texte intégral est accessible chez l'éditeur. DOI: 10.1088/1742-6596/2503/1/012031.