Simplified Method for the Seismic Design of Low-Rise, Shear Wall Base- Isolated Buildings
Auteur(s): |
Arturo Tena-Colunga
|
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | The Open Construction and Building Technology Journal, décembre 2014, n. 1, v. 8 |
Page(s): | 22-33 |
DOI: | 10.2174/1874836801408010022 |
Abstrait: |
A simplified method for the seismic design of low-rise, base-isolated shear wall structures is proposed in MOC-2012. This simplified method is basically a hybrid method, where the design of the isolation system is a simpler version for the static method available in US guidelines for the design of base-isolated structures and the design of the superstructure essentially is an improved version of the simplified method for the seismic design of conventional low-rise shear wall structures of Mexican seismic codes. The application of this method and its effectiveness to obtain safe designs is illustrated with a practical example. It is anticipated this simple methodology would help promote the use of base isolation in low-rise shear wall structures and reduce their vulnerability when subjected to strong earthquakes. |
Copyright: | © 2014 Arturo Tena-Colunga, |
License: | Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original. |