Short steel and concrete columns under high temperatures
Auteur(s): |
A. E. P. G. A. Jacintho
V. P. Silva J. A. V. Requena R. C. C. Lintz L. A. G. Barbosa L. L. Pimentel |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Revista IBRACON de Estruturas e Materiais, août 2012, n. 4, v. 5 |
Page(s): | 530-547 |
DOI: | 10.1590/s1983-41952012000400007 |
Abstrait: |
The growing demand for knowledge about the effect of high temperatures on structures has stimulated increasing research worldwide. This article presents experimental results for short composite steel and concrete columns subjected to high temperatures in ovens with or without an axial compression load, numerically analyzes the temperature distribution in these columns after 30 and 60 minutes and compares them with experimental results. The models consist of concrete-filled tubes of three different thicknesses and two different diameters, and the concrete fill has conventional properties that remained constant for all of the models. The stress-strain behavior of the composite columns was altered after exposure to high temperatures relative to the same columns at room temperature, which was most evident in the 60-minute tests due to the higher temperatures reached. The computational analysis adopted temperature rise curves that were obtained experimentally. |