0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Seismic Upgrading of a Fire-Brigade Building by Base Isolation in Basel, Switzerland

Auteur(s):
Médium: article de revue
Langue(s): anglais
Publié dans: Structural Engineering International, , n. 3, v. 20
Page(s): 268-274
DOI: 10.2749/101686610792016880
Abstrait:

Recently, the main building of the professional fire brigade of the city and canton Basel-Stadt built in the year 1943 was placed on special seismic elastomeric bearings and sliding bearings. This is the first such seismic upgrading of an existing building, north of the European Alps. Compared to conventional strengthening, the building costs were significantly smaller, and no temporary transfer of the fire-brigade troops and operational facilities to an expensive provisional building was necessary. Moreover, the resulting seismic safety is considerably higher, and the vulnerability to a severe earthquake is essentially smaller than in the case of conventional strengthening. Therefore, softening instead of strengthening was a much better upgrading strategy.

  • Informations
    sur cette fiche
  • Reference-ID
    10058067
  • Publié(e) le:
    10.11.2010
  • Modifié(e) le:
    13.08.2014
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine