Seismic Response Control of a Soft First-Story Building
Auteur(s): |
Yasuhiro Hayabe
(Design Division, Taisei Corporation, 1-25-1 Nishi-shinjuku, Shinjuku-ku, Tokyo 163-0606, Japan)
Yuichi Watanabe (Design Division, Taisei Corporation, 1-25-1 Nishi-shinjuku, Shinjuku-ku, Tokyo 163-0606, Japan) |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Journal of Disaster Research, 1 juin 2009, n. 3, v. 4 |
Page(s): | 239-245 |
DOI: | 10.20965/jdr.2009.p0239 |
Abstrait: |
A structure with a building plane 7.75 × 8.35 m, 47.8 m high, and having a height/width aspect ratio exceeding 6 has a building response that is difficult to control in both seismic and wind loading. We therefore changed the vibration mode from rocking to swaying by softening first-story translation stiffness and concentrating building deformation to make the first story energy-absorbing. The soft first-story structure we introduce involves (1) stiffening the structure above the second story, (2) making first-story columns laterally flexible and axially rigid, and (3) developing a response-hardening oil damper. The sections below detail these structural elements and dynamic response control performance against wind and seismic loading through time-history response analysis. |
License: | Cette oeuvre a été publiée sous la license Creative Commons Attribution - Pas de Modification 4.0 (CC-BY-ND 4.0). Il est autorisé de partager l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous n'avez pas l'autorisation de distribuer une oeuvre modifiée. |
0.46 MB
- Informations
sur cette fiche - Reference-ID
10684988 - Publié(e) le:
21.06.2022 - Modifié(e) le:
10.05.2023