0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Seismic Damage Assessment for Isolated Buildings with a Substructure Method

Auteur(s):


Médium: article de revue
Langue(s): anglais
Publié dans: Buildings, , n. 8, v. 12
Page(s): 1185
DOI: 10.3390/buildings12081185
Abstrait:

A seismic damage detection method for isolated buildings is proposed based on substructure identification with incomplete contaminated measurements. A concept of a pseudo substructure with virtual conditions is constructed for the proof of the proposed substructure identification method. This identification method is implemented in a two-stage procedure. The interface forces of the target substructure are identified in the first stage and the parameter of the target substructure is updated in the second stage, which can enable the parameter identification of substructures with unknown input. Two computational methods are also proposed to improve the two-stage identification algorithm. A sub-time zone identification method is utilized to reduce the computation effort and the simultaneous identification of the unknown force and initial structural responses is presented in the first_stage identification for a general case in practical engineering. Numerical studies of a shear frame with nonlinear base isolation subject to earthquake ground motion are investigated to validate the proposed seismic damage detection method. A fourteen-storey concrete shear wall building with a two-storey steel frame on top connected by isolation is studied experimentally with shaking table tests to further validate the proposed method. The shear wall structure is taken as the target substructure for damage assessment. The interface force and parameter of the concrete shear wall building are estimated with the proposed method. Results from both the numerical simulations and laboratory tests indicate that the proposed method can estimate seismic isolated structures and detect damage effectively based on only a few accelerometers. It is also demonstrated that the parameter identification results based on the structure response measurement during the earthquake are more accurate than the identification with post-earthquake structural response measurement.

Copyright: © 2022 by the authors; licensee MDPI, Basel, Switzerland.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10688680
  • Publié(e) le:
    13.08.2022
  • Modifié(e) le:
    10.11.2022
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine