Seismic Behavior of Precast Prestressed Concrete Frame with Hinge-Relocated Mortise–Tenon Connections
Auteur(s): |
Hanxi Zhao
Noriyuki Takahashi |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Buildings, 25 août 2024, n. 9, v. 14 |
Page(s): | 3007 |
DOI: | 10.3390/buildings14093007 |
Abstrait: |
To satisfy the easy-construction demands of precast concrete (PCa) frames after an earthquake, a PCa frame with mortise–tenon (MT) connections is proposed in this paper. MT connections are secured solely through the binding force of unbonded prestressed tendons without grouting for easy construction. The design and construction of the joint are detailed. During an earthquake, the hinge system of the connection allows for slight rotational movements. Finite element analysis was employed to assess the joint’s hysteresis behavior, revealing a three-stage earthquake response mechanism: closing, hinge relocation, and self-centering. Based on the hysteresis performance of the beam and column in the precast prestressed concrete (PCaPC) frame, a seismic response model for PCaPC buildings was established. |
Copyright: | © 2024 by the authors; licensee MDPI, Basel, Switzerland. |
License: | Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original. |