0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Quantification of Moment–Rotation Relationship of Monolithic Precast Beam–Column Connections

Auteur(s):



Médium: article de revue
Langue(s): anglais
Publié dans: Buildings, , n. 1, v. 12
Page(s): 11
DOI: 10.3390/buildings12010011
Abstrait:

The accurate prediction of nonlinear structural behaviors under different seismic intensities is an important basis for seismic resilience assessments of building structures. The moment–rotation relationship is often used to characterize the seismic performance of connections, and is widely used in high-efficiency nonlinear structural analysis. In this paper, a method of calculating the curve using a four-linear equivalent model is presented, aiming to quantify the characteristic point parameters of the moment–rotation curves of monolithic precast beam–column (MPBC) connections for engineering design purposes. The method considered the contribution of the elastic flexure of beams and columns, the relative slip of beam longitudinal bars in the core zone, and the formation of plastic hinges at beam ends to the total deflection. Due to the presence of local complex configurations in MPBC connections, the fine fiber section method was used for moment–curvature analysis of critical beam sections. The determination of the sectional analysis processes was controlled by the strain of steel bars or concrete or their coupling effect. In addition, a two-step method was proposed to construct the moment–rotation relationship of cruciform beam–column connections for solving the deformation compatibility of beams on both sides of the column caused by asymmetric reinforcement and the strength difference between new and old concrete. To reflect the current manufacturing level of MPBC connections, 58 representative specimens reported in recent years were analyzed and classified as type 1–5. All types of MPBC connections and their 18 cast-in situ counterparts were calculated using the proposed method for both verification and quantification. The verification showed that the proposed method had good applicability to both cast-in situ and precast beam–column connections. The quantification showed that the characteristic point parameters were slightly different between these two connections. Accordingly, modification coefficients were suggested for MPBC connections to facilitate design.

Copyright: © 2021 by the authors; licensee MDPI, Basel, Switzerland.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10648343
  • Publié(e) le:
    07.01.2022
  • Modifié(e) le:
    01.06.2022
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine