0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Numerical Study of Smoke Distribution in Inclined Tunnel Fire Ventilation Modes Considering Traffic Conditions

Auteur(s): ORCID
ORCID

ORCID

ORCID

Médium: article de revue
Langue(s): anglais
Publié dans: Buildings, , n. 3, v. 13
Page(s): 714
DOI: 10.3390/buildings13030714
Abstrait:

Japan and Europe have adopted significantly different ventilation modes with regard to traffic conditions (with or without congestion). This study focuses on the smoke behavior of different ventilation modes by conducting a 3D CFD analysis of smoke distribution and CO concentration variation and then comparing these modes based on two groups (relatively low target velocity: 0 and 1 m/s; relatively high target velocity: 2 and 3 m/s). The considered fire size is 30 MW for four longitudinal gradients (0, 2, 4, and 6%). In the simulation results, velocities of both 0 and 1 m/s reveal good performance in maintaining the stratification of smoke and ensuring the safety of the environment in 10 min in the occurrence of traffic jams. However, in 15 min, the smoke conditions change. Thus, it is difficult to distinguish which ventilation mode (0 and 1 m/s) shows relatively better performance during traffic congestion. When traffic is uncongested, the comparison of Um = 2 and 3 m/s reveals that a target velocity of Um = 2 m/s (lower than critical velocity) can also prevent the risk of smoke on the upstream side because no descending phenomenon is observed. Moreover, Um = 2 m/s causes the relatively slow propagation of descending smoke, increasing the possibility of evacuation once a second traffic incident occurs on the downstream side of the fire source.

Copyright: © 2023 by the authors; licensee MDPI, Basel, Switzerland.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10712625
  • Publié(e) le:
    21.03.2023
  • Modifié(e) le:
    10.05.2023
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine