Numerical Simulation Study of Effect of Tunnel Slope on Smoke Propagation
Auteur(s): |
Dandan Wan
Yanfeng Li Yunfei Li Huiqiang Liu |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Journal of Physics: Conference Series, 1 janvier 2022, n. 1, v. 2179 |
Page(s): | 012023 |
DOI: | 10.1088/1742-6596/2179/1/012023 |
Abstrait: |
Tunnel slope is an important factor affecting smoke spreading for a stopped subway train on fire. In this paper, a multi-scale method where one-dimensional (1D) network is coupled with three-dimensional (3D) field simulation is used to calculate smoke and temperature distributions for a fire occurred in the middle part of the subway train in tunnel. The tunnel slopes of 0‰, 12‰, 21‰ and 30‰ are considered. By comparing the temperature distribution in a condition with natural ventilation and with 2 m/s longitudinal ventilation, we comprehensively analyzed temperature, smoke spread characteristics. Results show that tunnel slope has a great influence on temperature and smoke profile when slope is higher than 12‰. The temperature at 1.8m would exceed the safe limit of 60°C at 60 s after fire ignition. The larger the slope, the higher temperature would be in the train carriage. For a train fire scenario with natural ventilation, within initial 120 s period the train compartment could keep a safe evacuation condition. This research would provide reference for making right evacuation plan of subway tunnel fire. |
- Informations
sur cette fiche - Reference-ID
10670888 - Publié(e) le:
12.06.2022 - Modifié(e) le:
12.06.2022