Modelska ispitivanja utjecaja na kontrolu požarnog dima u cestovnim tunelima
Model tests of fire smoke control effects in highway tunnels
Médium: | article de revue |
---|---|
Langue(s): | croate |
Publié dans: | Građevinar, octobre 2020, n. 9, v. 72 |
Page(s): | 781-792 |
DOI: | 10.14256/jce.2671.2019 |
Abstrait: |
In this work, a typical tunnel 150 m in length is selected and modelled at a scale of 1:15 to assess its effects on smoke control. A total of 32 model tests on smoke flow pattern and longitudinal temperature distribution have been carried out based on the Froude similarity criterion. The results show that smoke control is affected by three factors, namely, the longitudinal airflow velocity, number of opened smoke-exhaust dampers, and fire power, out of which the longitudinal airflow velocity has the greatest effect on smoke control. |
Copyright: | © 2020 , |
License: | Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original. |
0.54 MB
- Informations
sur cette fiche - Reference-ID
10522590 - Publié(e) le:
09.12.2020 - Modifié(e) le:
10.05.2023