Model Test Study on the Antibreaking Technology of Reducing Dislocation Layer for Subway Interval Tunnel of the Stick-Slip Fracture
Auteur(s): |
Guang-yao Cui
Xue-lai Wang |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Advances in Civil Engineering, 2019, v. 2019 |
Page(s): | 1-9 |
DOI: | 10.1155/2019/4328103 |
Abstrait: |
Based on the background of the Line F2-3interval tunnel section of Jiujiawan in Urumqi Subway Line 1, this paper carries out the model test research on the antibreaking technology of the reducing dislocation layer in the tunnel section of the stick-slip fracture. The antibreaking effect of different locations and number of reducing dislocation layers in tunnel engineering is analyzed in this paper. The results show that when the double reducing dislocation layer, respectively, set between the surrounding rock and the primary support, and the primary support and the secondary lining, the antibreaking effect is the best. It is recommended to use this scheme for antibreaking design. The research results can provide reference for antibreaking design of traffic tunnels in active fault zones. |
Copyright: | © 2019 Guang-yao Cui and Xue-lai Wang et al. |
License: | Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original. |
3.37 MB
- Informations
sur cette fiche - Reference-ID
10376511 - Publié(e) le:
12.10.2019 - Modifié(e) le:
02.06.2021