0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Auteur(s):
ORCID
Médium: article de revue
Langue(s): anglais
Publié dans: Structural Engineering International, , n. 4, v. 12
Page(s): 295-300
DOI: 10.2749/101686602777965162
Abstrait:

It was observed that the girder and the stay cables vibrated laterally on a pedestrian cable-stayed bridge, when a large number of people crossed the bridge. This paper introduces how the engineers tackled this dynamic problem. Field measurements were carried out to investigate the mechanism of this vibration, finding out that the girder vibrated laterally. Vibration tests and numerical simulations were also conducted, suggesting that lateral dynamic forces induced by pedestrians were most likely to cause this vibration. Tuned liquid dampers were installed inside the box girder, which were found to be useful in decreasing the vibration level. The performance of the dampers ten years after the installation is also reported.

Ouvrages et projets

  • Informations
    sur cette fiche
  • Reference-ID
    10003171
  • Publié(e) le:
    25.08.2002
  • Modifié(e) le:
    13.08.2014
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine