0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

In Situ Testing Evaluation and Numerical Simulation of CFRP-Strengthened Reinforced Concrete Two-Way Slab with Initial Defect

Auteur(s):

Médium: article de revue
Langue(s): anglais
Publié dans: Buildings, , n. 1, v. 15
Page(s): 82
DOI: 10.3390/buildings15010082
Abstrait:

Carbon fiber-reinforced polymer (CFRP) composites, renowned for their high strength-to-weight ratio, are increasingly utilized in the strengthening of structural components. The application of CFRP for strengthening concrete components notably improves the cracking moment and substantially elevates the ultimate load-bearing capacity. This study focuses on a reinforced concrete (RC) two-way slab with an initial defect, specifically an initial deflection. To avert deformations or damages that could break structural integrity during service, the slab was strengthened by adhering CFRP to its underside. An in situ multi-stage loading test was conducted to evaluate the load-bearing capacity of the CFRP-strengthened slab, and the findings revealed that the mid-span deflection of the two-way slab incrementally reached 1.64 mm after the loading stages, with no observable signs of concrete cracking, debonding, or tearing of the CFRP-strengthened slab. The failure modes indicated a transition from concrete compression damage to CFRP anchorage stress concentrations, highlighting the effective stress distribution and load-sharing synergy provided by CFRP-strengthening. Additionally, a numerical model based on the finite element (FE) method was developed using ABAQUS to simulate the component’s performance during the loading process. A comparison between the measured mid-span deflection of the strengthened slab and the numerically simulated values confirmed the high accuracy and rationality of the simulation method. Utilizing the validated numerical model, an analysis of the slab’s ultimate load capacity was conducted, demonstrating that the CFRP strengthening technique effectively increased the load-bearing capacity of the initially imperfect RC two-way slab by nearly 50%.

Copyright: © 2024 by the authors; licensee MDPI, Basel, Switzerland.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10810190
  • Publié(e) le:
    17.01.2025
  • Modifié(e) le:
    17.01.2025
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine