Abstrait:

Alkali-activated concrete (AAC) features excellent mechanical properties and sustainability. The incorporation of crumb rubber (CR), recycled concrete aggregates (RCAs), and recycled steel fibers (RSFs) can further enhance environmental sustainability. This paper mainly investigated the dynamic behaviors of a novel rubberized AAC incorporating RCAs and RSFs (RuAAC) through Split-Hopkinson Pressure Bar (SHPB) tests. The variables included three types of RSF content (1%, 2% and 3%), five types of rubber content (0%, 5%, 20%, 35% and 50%) and five impact pressures (0.5 MPa, 0.6 MPa, 0.7 MPa, 0.8 MPa and 0.9 MPa). Dynamic stress–strain curves, dynamic strength, the dynamic increase factor (DIF), impact toughness and the synergistic effects of RSF and CR were discussed. The results show that increasing RSF and CR contents could improve the impact resistance of RuAAC under impact loading. The RuAAC exhibited significant strain rate sensitivity, and the sensitivity increased with larger contents of RSF and CR. The increase in strain rate sensitivity was more pronounced with higher CR contents, which was reflected in larger dynamic increase factor (DIF) values. Under high impact pressure, the impact toughness was obviously enhanced with higher RSF contents, while the contribution of increased CR content to impact toughness was not apparent, which may be attributed to the fact that this study only calculated the integral under the dynamic stress–strain curve before the peak stress to determine impact toughness, neglecting the potential contribution of CR particles after the peak point. The obvious strain sensitivity exhibited by the RuAAC in the SHPB tests indicated superior impact performance, making it particularly suitable for architectural structures prone to seismic or explosive impacts.

Copyright: © 2024 by the authors; licensee MDPI, Basel, Switzerland.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10760359
  • Publié(e) le:
    15.03.2024
  • Modifié(e) le:
    25.04.2024
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine