Hydrothermal Evaluation of Vernacular Housing: Comparing Case Studies of Waste PET Bottles, Stone, and Adobe Houses
Auteur(s): |
Flavio Roberto Ceja Soto
José de Jesús Pérez Bueno Maria Luisa Mendoza López Martín Hernández Chavela Martha Elva Pérez Ramos Alejandro Manzano-Ramírez |
---|---|
Médium: | article de revue |
Langue(s): | anglais |
Publié dans: | Buildings, 31 juillet 2022, n. 8, v. 12 |
Page(s): | 1162 |
DOI: | 10.3390/buildings12081162 |
Abstrait: |
This work shows the humidity and thermal evaluation of different case studies of houses. The analyses focused on room prototypes and houses built in different regions of Querétaro, México. Three different climatic zones were included with the evaluations of houses and prototypes. The assessments of internal and external parameters in residential buildings are also shown. The internal parameter measurements were done with hydro-thermometers and thermography images. Six structures were evaluated, one of the conventional housing materials and five of alternative or vernacular materials. The predicted mean vote (PMV) and the predicted percentage dissatisfied (PPD) were determined using the average temperature and relative humidity values, and they were considered to be dynamic because they can change depending on many factors. The six dwelling insulating properties were associated with their construction materials, design, location, and other factors. The six houses have many differences, but considering their behavior in their location, the two floor porous stone house got the best results. On the contrary, the flagstone house with a gabled roof of galvanized sheets had a cold perception despite many advantageous elements, failing to provide comfort in such a cold location. Contrasting these with other adobe constructions, the analyzed one had low thermal insulation, which was explained by its characteristics. PET and adobe uninhabited prototypes had medium to cold perceptions. The PET prototype has excellent and adjustable insulations, both on temperature and RH, considering the passive illumination and ventilation of its glass bottle skylights. |
Copyright: | © 2022 by the authors; licensee MDPI, Basel, Switzerland. |
License: | Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original. |
4.93 MB
- Informations
sur cette fiche - Reference-ID
10688604 - Publié(e) le:
13.08.2022 - Modifié(e) le:
10.11.2022