0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Hybrid system strategy on double skin façade to optimize thermal performance on research building

Auteur(s):

Médium: article de revue
Langue(s): anglais
Publié dans: IOP Conference Series: Earth and Environmental Science, , n. 1, v. 881
Page(s): 012048
DOI: 10.1088/1755-1315/881/1/012048
Abstrait:

One of the most efficient methods to optimize thermal performance in a building is the practical design of the façade. The double skin façade‘(DSF) is a crucial decision for handling the interaction between outdoor and indoor spaces. It also offers some spatial diversity in the design process. Recently, a lot of focus has been paid to it instead of the more traditionally glazed curtain wall. This is because of its potential to reduce energy effectively, achieve thermal comfort in the building, and save costs. The indoor spaces near to the glazed facades will become warm due to high incidence solar radiation on the East-West facades in Malaysia’s tropical environment. In the tropics, one of the solar heat gain reduction approaches is the use of double skin-facade (DSF). One of the fundamental components of the double-skin facade is the blinds. Blinds located in the cavity of the double-skinned facade and buffer the building from solar heat gain or perform the role of a pre-heater for ventilation air. In general, the temperature of the blinds is high, which is helpful in the cold period but problematic in the hot period. To minimize the cooling loads of the building, technological innovations for the shading system are considered. Plants can dissipate absorbed solar radiation into resistant and latent heat. Plants turn radiation into the latent heat. This paper aims to study the effectiveness of a double skin façade and explore improved innovative design for a double-skin façade design integrated with vertical green on research building to optimize thermal performance. This paper will collect data of the thermal performance of double skin façade, precedent study and run simulation analysis to achieve the aim of the paper.

Structurae ne peut pas vous offrir cette publication en texte intégral pour l'instant. Le texte intégral est accessible chez l'éditeur. DOI: 10.1088/1755-1315/881/1/012048.
  • Informations
    sur cette fiche
  • Reference-ID
    10780808
  • Publié(e) le:
    12.05.2024
  • Modifié(e) le:
    12.05.2024
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine