Flexural Elastic Buckling Stress of Batten Type Light Gauge Built-Up Member

Auteur(s): (Nagoya Institute of Technology, Dept. of Civil Engineering , Gokiso-cho, Showa-ku, Nagoya, Aichi, Japan)
(Frontier Research Institute for Information Science)
Médium: article de revue
Langue(s): anglais
Publié dans: Civil and Environmental Engineering Reports, , n. 2, v. 25
Page(s): 161-172
DOI: 10.1515/ceer-2017-0027
Abstrait:

In Japan, built-up member composed with light gauge is used for studs of shear wall. Flexural buckling stress of built-up compression member is evaluated by effective slenderness ratio. The effective slenderness ratio of light gauge built-up compression member is proposed for heavy sections; however, it is not verified that it can be adopted in light gauge. In this paper, full scale testing of light gauge built-up members are conducted. From the test results, it is shown that current Standard overestimates the buckling strength. Based on energy equilibrium theory, modified effective slenderness ratio for light gauge built-up member is derived. The validity of the modified effective slenderness ratio is shown with test results.

Structurae ne peut pas vous offrir cette publication en texte intégral pour l'instant. Le texte intégral est accessible chez l'éditeur. DOI: 10.1515/ceer-2017-0027.